A crack that ignored the control joint
Stock photo: a wide crack running across a sawn control joint in a weathered slab.
- What it is
- A crack that wanders across the panel and through or past a sawn control joint, instead of opening inside the joint where it was supposed to.
- Likely causes
- A joint cut too shallow or too late to work (NRMCA CIP 6 asks for a groove at least a quarter of the slab’s depth, sawn within 4 to 12 hours of finishing), panels too long or out of square, or ground settling under one side.
- Repair options
- If both sides are still level, clean the crack out and seal it with a flexible sealant so water and salt stay out of the base. A rigid filler cracks loose the first time the slab moves.
- When repair won’t last
- When one side keeps dropping. Then it is a support problem, and the answer is lifting the low panel or replacing it.
Worth paying to fix? Sealing, yes: it’s a small job that protects the base. It won’t make the line disappear.